HC40C16T/R-2

Built-in temperature compensation

Adjustable detection range

Nickel-plated copper housing (stainless steel customizable)

IP67 protection rating

Reverse polarity protection & transient overvoltage protection

-20°C~+80°C Operating Temperature
40.0KHz±2% Center Frequency
110dB min(40Khz 30cm 0dB=20ubar) Transmit Sensitivity
-70dB min(40Khz 30cm 0dB=10V/pa) Receive Sensitivity

Specifications

Parameters below support engineering selection and installation evaluation.

Center Frequency 40.0KHz±2%
Transmit Sensitivity 110dB min(40Khz 30cm 0dB=20ubar)
Receive Sensitivity -70dB min(40Khz 30cm 0dB=10V/pa)
Static Capacitance 2400Pf±20%
Beam Angle 85°±15° (-6dB)
Peak Voltage 60Vp-p (Pulse)
Angle 60*120°
Resolution 10mm
Operating Temperature -20°C~+80°C
Storage Temperature -40°C~+80°C
Housing Material Aluminum housing
Cable Length 2m