Close

Ultrasonic Module

HC200F18GM-I/U-1000-V1

Home / Products / Ultrasonic Module / HC200F18GM-I/U-1000-V1
Product Details

HC200F18GM-I/U-1000-V1

Built-in temperature compensation

Adjustable detection range

Nickel-plated copper housing (stainless steel customizable)

IP67 protection rating

Reverse polarity protection & transient overvoltage protection

60-1000mm Measuring Range
0~60mm Blind Zone
10~30VDC or 15~30VDC Operating Voltage
-20°C~+80°C Operating Temperature

Specifications

Parameters below support engineering selection and installation evaluation.

Measuring Range 60-1000mm
Blind Zone 0~60mm
Standard Target 300*300mm
Angle 10°
Repeatability 0.003
Operating Voltage 10~30VDC or 15~30VDC
Temperature Drift 0.05%/°C (Built-in temperature compensation)
Linearity <1%
Resolution 0.1% of full scale (minimum 0.5 mm)
Response Time 125ms
EMC GB/T17626.2-2006 / GB/T17626.4-2008
Power Consumption 20ma
Protection Circuit Reverse polarity protection & transient overvoltage protection
Operating Temperature -20°C~+80°C
Storage Temperature -40°C~+80°C
Housing Material Nickel-plated copper housing (stainless steel customizable)
Cable Length 2m

Values are based on standard test conditions. Confirm final performance for your application.

Dimensional Drawing
HC200F18GM-I/U-1000-V1 dimensional drawing
Wiring Diagram
HC200F18GM-I/U-1000-V1 wiring diagram